FC0054607-00 A
Fibre Channel and Converged Network
Adapters for VMware ESX/ESXi 4.0
Users Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 61 62

Podsumowanie treści

Strona 1 - User’s Guide

FC0054607-00 AFibre Channel and Converged NetworkAdapters for VMware ESX/ESXi 4.0User’s Guide

Strona 2 - Document Revision History

x FC0054607-00 A Text within square brackets indicates optional parameters. For exampleiscli [optional parameters] [Command Variable] Tex t i n b

Strona 3 - Table of Contents

FC0054607-00 A xiVisit the QLogic support Web site listed in Contact Information for the latest firmware and software updates.AvailabilityQLogic Tech

Strona 4 - List of Tables

xii FC0054607-00 ANotes

Strona 5 - FC0054607-00 A v

FC0054607-00 A 1-11 Hardware and Software ComponentsThis chapter provides details about QLogic Fibre Channel and Converged Network Adapters in VMware

Strona 6

1–Hardware and Software ComponentsHardware Components1-2 FC0054607-00 AFigure 1-1 Adapter ComponentsTable 1-1. Adapter Component DetailsCallout Numb

Strona 7 - Preface

1–Hardware and Software ComponentsSoftware ComponentsFC0054607-00 A 1-3Software ComponentsThis section describes the following QLogic adapter softwar

Strona 8 - What’s in This Guide

1–Hardware and Software ComponentsSupported QLogic Adapters1-4 FC0054607-00 AFirmwareThe firmware module performs most of the Fibre Channel and FCoE

Strona 9 - Documentation Conventions

FC0054607-00 A 2-12 InstallationThis chapter provides the following installation information: Supported Features “Installing the Hardware” on page

Strona 10 - Technical Support

2–InstallationInstalling the Hardware2-2 FC0054607-00 A Support for MSI-X—on 4/8Gb Fibre Channel and Converged Network Adapters. Support for VMware

Strona 11 - Knowledge Database

2–InstallationInstalling the DriverFC0054607-00 A 2-35. Refasten the adapter's retaining bracket using the existing screw or lever.6. Close the

Strona 12

ii FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideInformation furnished in this manual is believed t

Strona 13 - 1 Hardware and Software

2–InstallationInstalling SANsurfer Management Tools2-4 FC0054607-00 AInstalling SANsurfer FC HBA ManagerTo run SANsurfer FC HBA Manager on a VMware E

Strona 14 - Callout

2–InstallationInstalling SANsurfer Management ToolsFC0054607-00 A 2-52. Click the by Operating System button, and then select Fibre Channel Adapters,

Strona 15 - Software Components

2–InstallationInstalling SANsurfer Management Tools2-6 FC0054607-00 Ac. In the command window, type hostname, and then press ENTER.9. On the ESX Host

Strona 16 - Supported QLogic Adapters

2–InstallationInstalling SANsurfer Management ToolsFC0054607-00 A 2-73. Click Go.4. Under Management Tools, click SANsurfer FC HBA Manager (x86/x64).

Strona 17 - 2 Installation

2–InstallationInstalling SANsurfer Management Tools2-8 FC0054607-00 A4. On the VMware ESX/ESXi download page under Management Tools, click SANsurfer

Strona 18 - Installing the Hardware

FC0054607-00 A 3-13 ConfigurationQLogic Fibre Channel and Converged Network Adapters on VMware ESX/ESXi 4.0 configuration procedures include the foll

Strona 19 - Installing the Driver

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.03-2 FC0054607-00 ATo identify QLogic Fibre Channel and Converged Network Adapters us

Strona 20

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.0FC0054607-00 A 3-3To identify QLogic Fibre Channel and Converged Network Adapters us

Strona 21 - $ hostname

3–ConfigurationIdentifying QLogic Adapters on VMware ESX/ESXi 4.03-4 FC0054607-00 AFigure 3-2 Finding Adapters on VMware ESX/ESXi 4.0Driver informat

Strona 22 - 2-6 FC0054607-00 A

3–ConfigurationUsing the QLogic Fast!UTIL BIOS UtilityFC0054607-00 A 3-5 NPIV Supported indicates whether the adapter port supports NPIV. If Yes, th

Strona 23 - FC0054607-00 A 2-7

FC0054607-00 A iiiTable of ContentsPrefaceIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Strona 24

3–ConfigurationVerifying That the Driver is Loaded3-6 FC0054607-00 A Select Host Adapter setting enables you to select a specific adapter, if you ha

Strona 25 - 3 Configuration

3–ConfigurationConfiguring the Driver ParametersFC0054607-00 A 3-7Figure 3-3 Verifying That the Driver is LoadedConfiguring the Driver ParametersUse

Strona 26 - Using Console OS

3–ConfigurationConfiguring the Driver Parameters3-8 FC0054607-00 Awhere <options> is one of the configurable parameters listed in Table 3-1 on

Strona 27

3–ConfigurationDeploying NPIV for VMware ESX/ESXi 4.0FC0054607-00 A 3-9Deploying NPIV for VMware ESX/ESXi 4.0QLogic Fibre Channel and Converged Netwo

Strona 28 - 3-4 FC0054607-00 A

3–ConfigurationMonitoring NPIV Virtual Ports from SANsurfer3-10 FC0054607-00 AVMware ESX/ESXi 4.0 enables NPIV support on QLogic 4Gb/8Gb Fibre Channe

Strona 29 - FC0054607-00 A 3-5

3–ConfigurationMonitoring NPIV Virtual Ports from SANsurferFC0054607-00 A 3-11Figure 3-4 SANsurfer FC HBA Manager Showing NPIVWhen you select an ind

Strona 30 - $ vmkload_mod -l

3–ConfigurationConfiguring Boot from SAN3-12 FC0054607-00 AFigure 3-5 Virtual Port Information Page in SANsurferConfiguring Boot from SANBoot from S

Strona 31 - # esxcfg-module -g qla2xxx

3–ConfigurationConfiguring Boot from SANFC0054607-00 A 3-13VMware ESX/ESXi 4.0 provides boot from SAN capability on QLogic Fibre Channel Adapters. Fo

Strona 32

3–ConfigurationConfiguring Boot from SAN3-14 FC0054607-00 A7. After the Host Adapter BIOS is enabled, select the boot device as shown in the followin

Strona 33 - Table Footnotes

FC0054607-00 A A-1A TroubleshootingThis appendix provides the following methods of determining the status of the adapters and finding solutions to co

Strona 34 - 3-10 FC0054607-00 A

iv FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideUsing the QLogic Fast!UTIL BIOS Utility . . . . .

Strona 35 - FC0054607-00 A 3-11

A–TroubleshootingTroubleshooting with LEDsA-2 FC0054607-00 ATable A-2. QLA24xx/QLE24xx/QEM2462 Adapter LED SchemeYellow LED Green LED Amber LED Activ

Strona 36 - Configuring Boot from SAN

A–TroubleshootingDynamic Extended LoggingFC0054607-00 A A-3 Dynamic Extended LoggingThe QLogic driver provides a mechanism to dynamically enable exte

Strona 37 - FC0054607-00 A 3-13

A–TroubleshootingTroubleshooting with Driver LogsA-4 FC0054607-00 AWhen the logging is enabled, the driver version in the /proc/scsi/qla2xxx/<adap

Strona 38

A–TroubleshootingTroubleshooting with Driver LogsFC0054607-00 A A-5Aug 18 15:15:13 localhost vmkernel: 0:00:00:34.550 cpu6:4109)<6>qla2xxx 0000

Strona 39 - A Troubleshooting

A–TroubleshootingTroubleshooting with Driver LogsA-6 FC0054607-00 ATable A-6 lists the more common driver log messages and provides an explanation of

Strona 40

A–TroubleshootingTroubleshooting with Driver LogsFC0054607-00 A A-7"scsi(%d): RSCN,..."Driver received a registered state change notificati

Strona 41 - Dynamic Extended Logging

A–TroubleshootingTroubleshooting with Driver LogsA-8 FC0054607-00 A"WARNING qla2xxx: Couldn't allocate host from scsi layer!"Indicates

Strona 42

A–TroubleshootingDebugging Using Proc InformationFC0054607-00 A A-9Debugging Using Proc InformationThe driver /proc/scsi/qla2xxx/<adapter_number&g

Strona 43

A–TroubleshootingCollecting System Logs for TroubleshootingA-10 FC0054607-00 ACollecting System Logs for TroubleshootingTo collect all relevant data

Strona 44

FC0054607-00 A Glossary-1GlossaryadapterThe board that interfaces between the host system and the target devices. Adapter is synonymous with host bus

Strona 45

FC0054607-00 A vFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuideA-6 Common Driver Log Messages . . . . . . . . . . .

Strona 46

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-2 FC0054607-00 AcacheA temporary high-speed storage (memo

Strona 47

FC0054607-00 A Glossary-3Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guidefabric switchAlso, switched fabric. Connect

Strona 48 - Frequently Seen Issues

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-4 FC0054607-00 AISLInter-switch link. The connection betw

Strona 49

FC0054607-00 A Glossary-5Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuideN_PortNode port. A port that connects by a

Strona 50 - Glossary-2 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-6 FC0054607-00 AThis is important to the driver when sele

Strona 51 - FC0054607-00 A Glossary-3

FC0054607-00 A Glossary-7Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s GuidetargetThe storage-device endpoint of a SCSI

Strona 52 - Glossary-4 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideGlossary-8 FC0054607-00 ANotes

Strona 53 - FC0054607-00 A Glossary-5

FC0054607-00 A Index-1IndexAacronyms, definitions of Glossary-1adapter port beacon, definition of Glossary-1adapter port, definition of Glossary-1

Strona 54 - Glossary-6 FC0054607-00 A

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideIndex-2 FC0054607-00 Adeviceboot, configuring 3-5definition of G

Strona 55 - FC0054607-00 A Glossary-7

FC0054607-00 A Index-3Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guideinstalling 2-1driver 2-3hardware 2-2SANsurf

Strona 56 - Glossary-8 FC0054607-00 A

vi FC0054607-00 AFibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideNotes

Strona 57 - FC0054607-00 A Index-1

Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0 User’s GuideIndex-4 FC0054607-00 ANPIVdefinition of Glossary-5deploying 3-9v

Strona 58 - Index-2 FC0054607-00 A

FC0054607-00 A Index-5Fibre Channel and Converged Network Adapters for VMware ESX/ESXi 4.0User’s Guidesupportedadapters 1-4features 2-1system logs

Strona 59 - FC0054607-00 A Index-3

© 2009 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic and the QLogic logo are register

Strona 60 - Index-4 FC0054607-00 A

FC0054607-00 A viiPreface QLogic provides a portfolio of Fibre Channel Adapters, Intelligent Ethernet Adapters, and Converged Network Adapters on the

Strona 61 - FC0054607-00 A Index-5

viii FC0054607-00 A SANsurfer FC HBA CLI User’s Guide (part number SN0054614-00) SANsurfer FC HBA CLI release notes and ReadMe fileRelated VMware d

Strona 62

FC0054607-00 A ix 2 Installation details the supported features and covers installation of hardware, drivers, and SANsurfer® management tools. 3 Co