16 Release Notes for Sun Storage 6580 and 6780 Arrays • March 2010
Hardware Issues
This section describes general issues related to Sun Storage 6580 and 6780 Arrays
hardware and firmware.
Replacing CRUs/FRUs in Less Than 15 Minutes
Caution – Without adequate ventilation and air circulation, the controller tray will
overheat resulting in potential damage to all customer-replaceable units (CRUs) or
field-replaceable units (FRUs). Do not allow any CRU/FRU slot to remain empty for
an extended time. Replace the failed CRU/FRU within 15 minutes.
System Cabinet Doors Must Be Closed
Caution – The front and back doors of the system cabinet must be closed for
compliance to domestic and international EMI regulations as well as proper
equipment cooling. Do not block or cover the openings of the system cabinet. Cabinet
airflow is from front to back. Allow at least 30 inches (76.2 cm) in front of the cabinet,
and at least 24 (60.96 cm) inches behind the cabinet, for service clearance, proper
ventilation, and heat dissipation.
Intermittent Power Supply Failure Notification
Bug 6760395 – CAM logEvent messages intermittently reports power supply failures
and 12 seconds later changes to optimal. This is caused by devices not responding to
polling.
Workaround – No workaround required. You can ignore the failure messages.
The cfgadm -c unconfigure Command Unconfigures UTM LUNs
Only and Not Other Data LUNs (Solaris 10)
Bug 6362850 – The cfgadm -c unconfigure command unconfigures Universal
Transport Mechanism (UTM) LUNs only and not other data LUNs. When this
happens, you will not be able to unconfigure LUNs.
Workaround – Obtain Solaris 10 patch 118833-20 (SPARC) or patch 118855-16 (x86)
to fix this issue.