Qlogic Storage Networking (Unified Fabric Pilot) Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Networking Qlogic Storage Networking (Unified Fabric Pilot). Qlogic Storage Networking (Unified Fabric Pilot) Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 76
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
51031-00 A
Installation Guide
Storage Networking (Unified Fabric Pilot)
QLogic 8100 Series Adapters, QLogic 5800 Series Switches,
Cisco Nexus 5000 Series Switches, JDSU Xgig Platform
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - Installation Guide

51031-00 AInstallation GuideStorage Networking (Unified Fabric Pilot)QLogic 8100 Series Adapters, QLogic 5800 Series Switches,Cisco Nexus 5000 Series

Strona 2 - Document Revision History

PrefaceDocumentation Conventionsx 51031-00 A

Strona 3 - Table of Contents

51031-00 A 1-11 OverviewMartin (2010) defines a converged network as follows: "A unified data center fabric is a networking fabric that combines

Strona 4 - C References

1–Overview1-2 51031-00 A

Strona 5 - List of Figures

51031-00 A 2-12 PlanningSelecting a Test ArchitectureWhen planning the pilot of a unified network, it is important to choose both Fibre Channel and t

Strona 6 - List of Tables

2–PlanningWhere and How to Deploy2-2 51031-00 ACurrently, a Converged Network Adapter must always be connected to a switch that has DCB. There are tw

Strona 7 - Related Materials

51031-00 A 3-13 ArchitectureApproachThe test configuration described in this section was installed and validated at the QLogic NETtrack Developer Cen

Strona 8

3–ArchitectureReference Architecture Description3-2 51031-00 AFigure 3-1. Reference Architecture Diagram

Strona 9 - 51031-00 A ix

3–ArchitectureReference Architecture Description51031-00 A 3-3Equipment DetailsTable 3-1 lists the referenced architecture equipment. Table 3-2 lists

Strona 10 - Documentation Conventions

3–ArchitectureReference Architecture Description3-4 51031-00 A

Strona 11 - 1 Overview

51031-00 A 4-14 InstallationThis section describes how to set up an FCoE environment. It assumes a general understanding of SAN administration concep

Strona 12 - 1-2 51031-00 A

ii 51031-00 AInstallation Guide Storage Networking (Unified Fabric Pilot)Information furnished in this manual is believed to be accurate and reliable

Strona 13 - 2 Planning

4–InstallationEquipment Installation and Configuration4-2 51031-00 AEquipment Installation and ConfigurationThis section focuses on the converged net

Strona 14 - 2-2 51031-00 A

4–InstallationEquipment Installation and Configuration51031-00 A 4-3Install the Adapter DriversTo install the FCoE and Ethernet drivers:1. Go to the

Strona 15 - 3 Architecture

4–InstallationEquipment Installation and Configuration4-4 51031-00 AInstall SANsurfer FC HBA ManagerTo install SANsurfer® FC HBA Manager:1. Go to the

Strona 16 - 3-2 51031-00 A

4–InstallationEquipment Installation and Configuration51031-00 A 4-5CablingTo connect the Fibre Channel and Ethernet cables:1. Connect the Fibre Chan

Strona 17 - Equipment Details

4–InstallationEquipment Installation and Configuration4-6 51031-00 AConfiguring DCB on a Nexus Switch To enable PFC, ETS, and DCB functions on a Cisc

Strona 18 - 3-4 51031-00 A

4–InstallationEquipment Installation and Configuration51031-00 A 4-75. Configure qos policy-maps.policy-map type qos policy1 class type qos class-

Strona 19 - 4 Installation

4–InstallationEquipment Installation and Configuration4-8 51031-00 A10. Configure Ethernet port 1/3 to enable VLAN-1002-tagged FCoE traffic and VLAN-

Strona 20 - 4-2 51031-00 A

4–InstallationEquipment Installation and Configuration51031-00 A 4-9 bandwidth percent 50 Class-map (queuing): class-fcoe (match-any)

Strona 21 - Install the Adapter Drivers

4–InstallationVerify Equipment Connectivity4-10 51031-00 AVerify Equipment ConnectivityTo verify that all equipment is logged in and operating proper

Strona 22 - 4-4 51031-00 A

4–InstallationVerify Equipment Connectivity51031-00 A 4-114. When the LUNs have been created and all zoning is complete, use the management interface

Strona 23 - FCoE Switches

51031-00 A iiiTable of ContentsPrefaceIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiRe

Strona 24

4–InstallationVerify Equipment Connectivity4-12 51031-00 A Figure 4-7. SANsurfer Management Validation Screen 1 Figure 4-8. SANsurfer Management Vali

Strona 25

51031-00 A 5-15 Validation Methods for DCB and FCoEValidation Step 1—Verify PFC and ETS ParametersVerify the interoperability of the unified fabric d

Strona 26 - VLAN-2-tagged NIC traffic

5–Validation Methods for DCB and FCoEValidation Step 1—Verify PFC and ETS Parameters5-2 51031-00 Aa. Select the trigger mode.b. Set up the capture tr

Strona 27

5–Validation Methods for DCB and FCoEValidation Step 1—Verify PFC and ETS Parameters51031-00 A 5-3 pfc_enable value is the same for the adapter, swi

Strona 28 - Verify Equipment Connectivity

5–Validation Methods for DCB and FCoEValidation Step 1—Verify PFC and ETS Parameters5-4 51031-00 AValidation ResultsFigure 5-3 shows one trace captur

Strona 29 - 51031-00 A 4-11

5–Validation Methods for DCB and FCoEValidation Step 1—Verify PFC and ETS Parameters51031-00 A 5-5 From the trace, you can verify the following: DCB

Strona 30 - 4-12 51031-00 A

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation5-6 51031-00 AValidation Step 2—FIP ValidationThe next step is to verify FCoE in

Strona 31 - 5 Validation Methods for DCB

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation51031-00 A 5-74. The switch responds with the FIP Discovery Advertisement/Respon

Strona 32 - 5-2 51031-00 A

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation5-8 51031-00 AValidation ResultsFigure 5-6 shows the FIP test results between th

Strona 33 - 51031-00 A 5-3

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation51031-00 A 5-9In summary, the FIP link initialization process is successful—the

Strona 34 - Validation Results

iv 51031-00 AInstallation Guide Storage Networking (Unified Fabric Pilot)Validation Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 35 - 51031-00 A 5-5

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation5-10 51031-00 AUnlike end devices, the FCoE switches do not send FIP Keep Alive

Strona 36 - Figure 5-5. FIP Test Setup

5–Validation Methods for DCB and FCoEValidation Step 2—FIP Validation51031-00 A 5-11 Figure 5-11 shows the time difference between the last FIP Keep

Strona 37 - Validation Process

5–Validation Methods for DCB and FCoEValidation Step 3—FCoE Function and I/O Tests5-12 51031-00 AValidation Step 3—FCoE Function and I/O TestsFigure

Strona 38

5–Validation Methods for DCB and FCoEValidation Step 3—FCoE Function and I/O Tests51031-00 A 5-133. Configure the test as follows: MLTT test pattern

Strona 39 - Virtual Link Maintenance

5–Validation Methods for DCB and FCoEValidation Step 3—FCoE Function and I/O Tests5-14 51031-00 ASimilar to previous test results, the captured FCoE

Strona 40 - Alive Frame

5–Validation Methods for DCB and FCoEValidation Step 4—Validate PFC and Lossless Link51031-00 A 5-15Validation Step 4—Validate PFC and Lossless LinkT

Strona 41 - 51031-00 A 5-11

5–Validation Methods for DCB and FCoEValidation Step 4—Validate PFC and Lossless Link5-16 51031-00 A3. To validate that PFC Pause frames are sent to

Strona 42

5–Validation Methods for DCB and FCoEValidation Step 4—Validate PFC and Lossless Link51031-00 A 5-17As described earlier, the Expert software analyze

Strona 43

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification5-18 51031-00 ATable 5-2 shows some of the statistics reported by Expert softw

Strona 44

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification51031-00 A 5-192. Run all the tests with the Write configuration (Figure 5-18)

Strona 45

51031-00 A vInstallation Guide Storage Networking (Unified Fabric Pilot)List of FiguresFigure Page3-1 Reference Architecture Diagram . . . . . . . .

Strona 46

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification5-20 51031-00 A7. Use Expert to analyze the capture, and verify the following:

Strona 47 - Statistics

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification51031-00 A 5-21Figure 5-21 shows that the FCoE traffic is read at the rate of

Strona 48

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification5-22 51031-00 AFigure 5-23 shows how to enable a cross-port analysis in Expert

Strona 49

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification51031-00 A 5-23The next step is to verify that the switch allows more TCP traf

Strona 50

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification5-24 51031-00 AFigure 5-26 shows the relationship between FCoE, TCP, and pause

Strona 51 - 51031-00 A 5-21

5–Validation Methods for DCB and FCoEValidation Step 5—ETS Verification51031-00 A 5-25Exchange Completion Time (Latency Monitor)Latency is the measur

Strona 52 - 5-22 51031-00 A

5–Validation Methods for DCB and FCoEValidation Step 6—iSCSI Function and I/O Test5-26 51031-00 AValidation Step 6—iSCSI Function and I/O Test This t

Strona 53 - Figure 5-25. LAN Traffic Only

5–Validation Methods for DCB and FCoEValidation Step 6—iSCSI Function and I/O Test51031-00 A 5-27 Queue depth: eight.9. Capture a trace for the iSCS

Strona 54 - 5-24 51031-00 A

5–Validation Methods for DCB and FCoEValidation Step 6—iSCSI Function and I/O Test5-28 51031-00 ATable 5-5 lists the average, minimum, and maximum da

Strona 55 - 51031-00 A 5-25

5–Validation Methods for DCB and FCoEValidation Step 7—Virtualization Verification51031-00 A 5-29Validation Step 7—Virtualization VerificationThis va

Strona 56

vi 51031-00 AInstallation Guide Storage Networking (Unified Fabric Pilot)5-28 iSCSI Traffic Performance Validation Setup. . . . . . . . . . . . . . .

Strona 57

5–Validation Methods for DCB and FCoEValidation Step 7—Virtualization Verification5-30 51031-00 A6. Configure the test as follows: Trigger: any PFC

Strona 58 - Applications

5–Validation Methods for DCB and FCoEValidation Step 7—Virtualization Verification51031-00 A 5-31Table 5-6 lists the average minimum and maximum thro

Strona 59

5–Validation Methods for DCB and FCoEValidation Step 7—Virtualization Verification5-32 51031-00 AIn summary, multiple factors may determine the behav

Strona 60

51031-00 A A-1A Hardware and SoftwareCisco Unified Fabric SwitchThe Cisco Nexus 5000 Series switch enables a high-performance, standards-based, Ether

Strona 61 - Switch Port

A–Hardware and SoftwareJDSU (formerly Finisar) Equipment and SoftwareA-2 51031-00 AJDSU (formerly Finisar) Equipment and SoftwareJDSU XgigJDSU Xgig®

Strona 62 - 5-32 51031-00 A

A–Hardware and SoftwareQLogic QLE8142 Converged Network Adapter51031-00 A A-3QLogic QLE8142 Converged Network AdapterThe QLogic QLE8142 Converged Net

Strona 63

A–Hardware and SoftwareQLogic 5800V Series Fibre Channel SwitchA-4 51031-00 A

Strona 64 - JDSU Xgig

51031-00 A B-1B Data Center Bridging TechnologyThe following descriptions of Enhanced Ethernet were taken from Ethernet: The Converged Network Ethern

Strona 65 - 51031-00 A A-3

B–Data Center Bridging TechnologyData Center Bridging (DCB)B-2 51031-00 AEnhanced Transmission Selection (ETS) protocol addresses the bandwidth alloc

Strona 66 - A-4 51031-00 A

B–Data Center Bridging TechnologyData Center Bridging (DCB)51031-00 A B-3Figure B-1. Priority Flow ControlFibre Channel Over EthernetFCoE is an ANSI

Strona 67 - B Data Center Bridging

51031-00 A viiPrefaceThis document describes how to install and certify a pilot unified fabric configuration. This configuration demonstrates lossles

Strona 68 - Priority Flow Control

B–Data Center Bridging TechnologyData Center Bridging (DCB)B-4 51031-00 AiSCSIThe Internet Small Computer Systems Interface (iSCSI) is a SCSI mass st

Strona 69 - Fibre Channel Over Ethernet

51031-00 A C-1C ReferencesFibre Channel over Ethernet Design Guide, Cisco and QLogic (2010), QLogic adapters and Cisco Nexus 5000 Series switches, Ci

Strona 70 - B-4 51031-00 A

C–ReferencesC-2 51031-00 A

Strona 71

51031-00 A Index-1IndexAadapters 4-2, 4-3architecture 2-1, 3-1audience viiCcabling 4-1, 4-5configuration 4-1connectivity 4-10conventions viiiconverge

Strona 72 - C-2 51031-00 A

Installation Guide Storage Networking (Unified Fabric Pilot)Index-2 51031-00 Aorganizational ownership 2-1PPFC - see priority flow controlplanning 2

Strona 74 - Index-2 51031-00 A

Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.comInternational Office

Strona 75

PrefaceDocumentation Conventionsviii 51031-00 AThe Ethernet Alliance has white papers that further describe Enhanced Ethernet: http://www.ethernetall

Strona 76

PrefaceDocumentation Conventions51031-00 A ix Text in italics indicates terms, emphasis, variables, or document titles. For example: For a complete

Komentarze do niniejszej Instrukcji

Brak uwag