Qlogic SANsurfer FC/CNA HBA CLI Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Serwery Qlogic SANsurfer FC/CNA HBA CLI. Using Storage Center with FCoE and Linux Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Using Storage Center with FCoE and Linux
Dell Compellent Storage Center
Daniel Tan, Product Specialist
Dell Compellent Technical Solutions
November 2013
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - November 2013

Using Storage Center with FCoE and Linux Dell Compellent Storage Center Daniel Tan, Product Specialist Dell Compellent Technical Solutions November 2

Strona 2 - Revisions

10 Dell Compellent Using Storage Center with FCoE and Linux At this point, the Linux install process can proceed. As is reflected in the Redhat Ente

Strona 3 - Table of contents

11 Dell Compellent Using Storage Center with FCoE and Linux Figure 6 Select the boot from SAN Storage Center volume as the installation target It’

Strona 4 - Executive summary

12 Dell Compellent Using Storage Center with FCoE and Linux In line with the Redhat Enterprise Linux Best Practices guide (see Appendix A), the CNA

Strona 5

13 Dell Compellent Using Storage Center with FCoE and Linux # scli Scanning QLogic FC HBA(s) and device(s), please wait... - SANsurfer FC/CNA HBA

Strona 6

14 Dell Compellent Using Storage Center with FCoE and Linux 3: Return to Previous Menu Note: 0 to return to Main Menu Enter Selection: In the out

Strona 7

15 Dell Compellent Using Storage Center with FCoE and Linux 1: Details 2: Raw 3: Return to Previous Menu Note: 0 to return to Main Menu Enter Se

Strona 8

16 Dell Compellent Using Storage Center with FCoE and Linux # cat ifcfg-eth0 DEVICE="eth0" #HWADDR="00:C0:DD:1B:A0:E0" NM_CON

Strona 9

17 Dell Compellent Using Storage Center with FCoE and Linux # cat ifcfg-eth1.10 DEVICE="eth1.10" ONBOOT="yes" BOOTPROTO=stati

Strona 10

18 Dell Compellent Using Storage Center with FCoE and Linux 172.16.26.4:3260,0 iqn.2002-03.com.compellent:5000d31000006924 Now that the targets hav

Strona 11

19 Dell Compellent Using Storage Center with FCoE and Linux Figure 7 Observe the iqn is represented by two (2) unique IP addresses Once the Server

Strona 12

2 Dell Compellent Using Storage Center with FCoE and Linux Revisions Date Revision Description Author Nov 2013 1.0 Initial release Daniel Tan

Strona 13 - HBA Model QLE8152

20 Dell Compellent Using Storage Center with FCoE and Linux Rescanning session [sid: 4, target: iqn.2002-03.com.compellent:5000d31000006924, portal:

Strona 14

21 Dell Compellent Using Storage Center with FCoE and Linux multipaths { multipath { uid 0 alias mpatha gid 0 wwid "36000d3100002d40000000

Strona 15

22 Dell Compellent Using Storage Center with FCoE and Linux Instead of using LVM, a file system will simply be laid across the entire volume. For mo

Strona 16

23 Dell Compellent Using Storage Center with FCoE and Linux which will then separate out management and configuration to each individual driver and

Strona 17

24 Dell Compellent Using Storage Center with FCoE and Linux 2 Leveraging traditional 10Gb Ethernet NICs in a converged environment with Linux In mo

Strona 18

25 Dell Compellent Using Storage Center with FCoE and Linux The “dcbtool” is used to configure the parameters needed to allow FCoE traffic over the

Strona 19

26 Dell Compellent Using Storage Center with FCoE and Linux Command: Set Config Feature: Priority Flow Control Port: eth5 Status: Successful # d

Strona 20

27 Dell Compellent Using Storage Center with FCoE and Linux # /usr/libexec/fcoe/dcbcheck.sh eth5 DCB is correctly configured for FCoE At this poin

Strona 21

28 Dell Compellent Using Storage Center with FCoE and Linux eth5 | 100 | 00:0d:ec:f9:35:80 eth4 | 300 | 00:0d:ec:f9:35:80 Linux will create entrie

Strona 22 - 1.3 Special considerations

29 Dell Compellent Using Storage Center with FCoE and Linux 0x2000001b2182c2a2 2.1 Performance considerations Despite being a software implementat

Strona 23

3 Dell Compellent Using Storage Center with FCoE and Linux Table of contents Revisions ...

Strona 24

30 Dell Compellent Using Storage Center with FCoE and Linux A Additional resources Dell Compellent Redhat Enterprise Linux (RHEL) 6x Best Practices

Strona 25

4 Dell Compellent Using Storage Center with FCoE and Linux Executive summary Managing and scaling network infrastructure is often an expensive propo

Strona 26

5 Dell Compellent Using Storage Center with FCoE and Linux 1 Leveraging Converged Network Adapters (CNAs) in a converged environment with Linux 1.

Strona 27

6 Dell Compellent Using Storage Center with FCoE and Linux Figure 1 CNA BIOS configuration

Strona 28

7 Dell Compellent Using Storage Center with FCoE and Linux In the advanced configuration options, notice the “Link Down Timeout” setting; configurin

Strona 29 - 2.2 Special considerations

8 Dell Compellent Using Storage Center with FCoE and Linux Once the appropriate zoning and connectivity configurations have been configured, the CNA

Strona 30 - A Additional resources

9 Dell Compellent Using Storage Center with FCoE and Linux After the Server Object has been created in the Storage Center, a boot volume can be crea

Komentarze do niniejszej Instrukcji