Qlogic SANsurfer iSCSI HBA CLI Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Networking Qlogic SANsurfer iSCSI HBA CLI. Qlogic SANsurfer iSCSI HBA CLI User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 80
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
SN0054621-00 B Page i
Q
Simplify
SANsurfer iSCSI HBA CLI Application
Users Guide
Command Line Interface for SANblade
iSCSI Host Bus Adapters
Przeglądanie stron 0
1 2 3 4 5 6 ... 79 80

Podsumowanie treści

Strona 1 - User’s Guide

SN0054621-00 B Page iQSimplifySANsurfer iSCSI HBA CLI ApplicationUser’s GuideCommand Line Interface for SANbladeiSCSI Host Bus Adapters

Strona 2 - Page ii SN0054621-00 B

1 – IntroductionTechnical Support1-2 SN0054621-00 BQNotes

Strona 3 - SN0054621-00 B Page iii

SN0054621-00 B 2-1Section 2 Getting Started2.1IntroductionSANsurfer iSCSI HBA CLI operates in one of the following modes: Interactive mode. SAN

Strona 4

2 – Getting StartedInteractive Mode2-2 SN0054621-00 BQThe Main Menu (see figure 2-1) displays. For example:Figure 2-1. SANsurfer iSCSI HBA CLI Main M

Strona 5 - Table of Contents

2 – Getting StartedNon-interactive ModeSN0054621-00 B 2-3Q2.3Non-interactive ModeType the following in a command window to start SANsurfer iSCSI HBA

Strona 6 - Page vi SN0054621-00 B

2 – Getting StartedNon-interactive Mode2-4 SN0054621-00 BQ-t-pb-pu, -pxN/A-pa-dspcap, -chapmap, -linkchap, -addchap, -defbidi, -edchap, -delchap, -l7

Strona 7 - SN0054621-00 B Page vii

SN0054621-00 B 3-1Section 3 Initial InstallationThe following requirements must be met before you can run SANsurfer iSCSI HBA CLI: The HBAs mus

Strona 8 - Table Page

3 – Initial InstallationInstallation Instructions3-2 SN0054621-00 BQFor example, a package for the Linux operating system can be named:iscli-1.0.35-0

Strona 9 - Introduction

3 – Initial InstallationInstallation InstructionsSN0054621-00 B 3-3Q3. The Destination Folder dialog box displays (see figure 3-2).Figure 3-2. Destin

Strona 10 - 1-2 SN0054621-00 B

3 – Initial InstallationInstallation Instructions3-4 SN0054621-00 BQ4. The Start menu entries dialog box displays (see figure 3-3).Figure 3-3. Start

Strona 11 - Getting Started

3 – Initial InstallationInstallation InstructionsSN0054621-00 B 3-5Q5. The Start copying files dialog box displays (see figure 3-4). Read the informa

Strona 12 - Port Alias:

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersQPage ii SN0054621-00 BInformation furnish

Strona 13 - Non-interactive Mode

3 – Initial InstallationUninstall Instructions3-6 SN0054621-00 BQactivate this feature. The start menu and desktop shortcuts are ready and active now

Strona 14

3 – Initial InstallationUninstall InstructionsSN0054621-00 B 3-7Q3.2.1WindowsPerform the following steps to uninstall SANsurfer iSCSI HBA CLI:1. From

Strona 15 - Initial Installation

3 – Initial InstallationUninstall Instructions3-8 SN0054621-00 BQ

Strona 16

SN0054621-00 B 4-1Section 4 Interactive Mode CommandsThe following sections describe the interactive command line options listed in table 2-1. S

Strona 17 - 3 – Initial Installation

4 – Interactive Mode CommandsHBA Options Menu4-2 SN0054621-00 BQ iSCSI name (HBA port iSCSI name. The QLogic manufacturing default name or a name th

Strona 18 - 3-4 SN0054621-00 B

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-3Q4.4.1HBA Network Settings MenuPerform the following steps to make changes to the HBA

Strona 19 - SN0054621-00 B 3-5

4 – Interactive Mode CommandsHBA Options Menu4-4 SN0054621-00 BQ4.4.1.2Configure IP Settings(Command Line Option -ipdhcp)This submenu allows you to e

Strona 20 - Uninstall Instructions

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-5Q4.4.1.2.2Using SLPBy default, the service locator protocol (SLP) is disabled.To enabl

Strona 21

4 – Interactive Mode CommandsHBA Options Menu4-6 SN0054621-00 BQ4.4.2.1Display Configured HBA Settings(Command Line Option -c)When this option is sel

Strona 22 - 3-8 SN0054621-00 B

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-7QFW_Sense_Buffer_Descaon, off When this parameter is on, the HBA expects the last data

Strona 23 - Interactive Mode Commands

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersQSN0054621-00 B Page iii

Strona 24 - HBA Options Menu

4 – Interactive Mode CommandsHBA Options Menu4-8 SN0054621-00 BQLarge_Framesaon, off This parameter defines the maximum length of an Ethernet frame.

Strona 25 - Display Network Settings

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-9QiSCSI_Header_Digests on, off When this parameter is on, iSCSi headers with CRC protec

Strona 26 - Using DHCP

4 – Interactive Mode CommandsHBA Options Menu4-10 SN0054621-00 BQiSCSI_Snack on, off When this parameter is on and the FW_Initiator_Mode parameter is

Strona 27 - HBA Firmware Settings Menu

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-11QDefaultTime2Retaina0–65535 secondsThis parameter indicates the maximum logout time (

Strona 28 - (Command Line Option -c)

4 – Interactive Mode CommandsHBA Options Menu4-12 SN0054621-00 BQTCP_SLP_SA on, off When this parameter is on, the HBA is enabled as an initiator to

Strona 29

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-13QTCP_Time_Stamp on, off When this parameter is on, a timestamp is placed in every tra

Strona 30

4 – Interactive Mode CommandsHBA Options Menu4-14 SN0054621-00 BQ4.4.2.2Change HBA Alias NameNOTE: This option is not available in non-interactive mo

Strona 31

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-15Qa. For each submenu, save the changes by typing the number for the Save changes and

Strona 32

4 – Interactive Mode CommandsHBA Options Menu4-16 SN0054621-00 BQ iSCSI_Strict_Login iSCSI_AliasEach setting is displayed with the current value in

Strona 33

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-17Q IP_Subnet_Mask IP_Gateway Primary_DNS SLP_AddressEach setting is displayed with

Strona 34

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersQPage iv SN0054621-00 B© 2005 QLogic Corpo

Strona 35

4 – Interactive Mode CommandsHBA Options Menu4-18 SN0054621-00 BQ4.4.2.3.6Configure Advanced SettingsThis option allows you to modify the following s

Strona 36 - Change HBA Alias Name

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-19Q4.4.2.5Update Firmware Image(Command Line Option -f)This option updates the firmware

Strona 37 - (Command Line Option -n)

4 – Interactive Mode CommandsHBA Options Menu4-20 SN0054621-00 BQ3. Make changes in the submenus, as described in the following sections: Display Bo

Strona 38 - Configure Device Settings

4 – Interactive Mode CommandsHBA Options MenuSN0054621-00 B 4-21Q4.4.3.3Set Primary Boot Target Information(Command Line Option -pbootcode)This optio

Strona 39 - Configure Basic Settings

4 – Interactive Mode CommandsHBA Information (Command Line Option -pinfo)4-22 SN0054621-00 BQ4.4.4HBA Restore Factory Defaults(Command Line Option -r

Strona 40 - (Command Line Option -rdf)

4 – Interactive Mode CommandsReset HBA (Command Line Option -b)SN0054621-00 B 4-23QFor example:iscli Main Menumain Interactive Menu------------------

Strona 41 - SN0054621-00 B 4-19

4 – Interactive Mode CommandsTarget Menu4-24 SN0054621-00 BQ4.7Target MenuBefore making a selection from the HBA Target Menu, perform the following s

Strona 42 - Set Bootcode Mode

4 – Interactive Mode CommandsTarget MenuSN0054621-00 B 4-25Q4.7.2Bind Target(Command Line Option -pb)This option persistently binds a specific target

Strona 43 - SN0054621-00 B 4-21

4 – Interactive Mode CommandsTarget Menu4-26 SN0054621-00 BQ TGTCPO_Timestamp TGT_TargetIPAddressEach setting is displayed with the current value i

Strona 44 - (Command Line Option -pinfo)

4 – Interactive Mode CommandsTarget MenuSN0054621-00 B 4-27Q Add a CHAP entry (see section 4.7.6.4) Add a default BIDI CHAP (see section 4.7.6.5)

Strona 45 - (Command Line Option -b)

SN0054621-00 B Page vTable of ContentsSection 1 Introduction1.1 Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 46 - (Command Line Option -t)

4 – Interactive Mode CommandsTarget Menu4-28 SN0054621-00 BQ3. The CHAP table is displayed. At the prompt CHAP Entry Number <0 for no CHAP>, do

Strona 47 - Configure Target Parameters

4 – Interactive Mode CommandsTarget MenuSN0054621-00 B 4-29Q4.7.6.6Edit a CHAP Entry(Command Line Option -edchap)Perform the following steps to edit

Strona 48 - (Command Line Option -pa)

4 – Interactive Mode CommandsDiagnostic Menu4-30 SN0054621-00 BQ4.7.7List LUN Information(Command Line Option -l)This option allows you to view the f

Strona 49

4 – Interactive Mode CommandsDiagnostic MenuSN0054621-00 B 4-31QMake changes in the submenus, as described in the following sections.After making cha

Strona 50 - Add a Default BIDI CHAP

4 – Interactive Mode CommandsDiagnostic Menu4-32 SN0054621-00 BQ4.8.3Perform Read/Write Buffer Test(Command Line Option -rwt)CAUTION! Before performi

Strona 51 - Delete a CHAP Entry

4 – Interactive Mode CommandsDiagnostic MenuSN0054621-00 B 4-33Q MACRxControlFrames. MAC received control frames MACRxDribble. MAC received dribble

Strona 52 - Diagnostic Menu

4 – Interactive Mode CommandsDisplay Vital Product Data (VPD) Information (Command Line Option -vpd)4-34 SN0054621-00 BQ iSCSIDataDigestErrorCount.

Strona 53 - (Command Line Option -lb)

SN0054621-00 B 5-1Section 5 Non-interactive Mode Commands5.1IntroductionWhen operating in non-interactive mode, the command format is as follows

Strona 54 - (Command Line Option -stat)

5 – Non-interactive Mode Commands-b (Reset HBA)5-2 SN0054621-00 BQThe positional parameters vary, depending on the command option specified. For exam

Strona 55 - SN0054621-00 B 4-33

5 – Non-interactive Mode Commands-l (List LUN Information)SN0054621-00 B 5-3Q5.5-g(Display General System Information)Type the following command to d

Strona 56 - Set Working Adapter

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersPage vi SN0054621-00 BQ4.4.2.3.3 Configure

Strona 57 - Non-interactive Mode Commands

5 – Non-interactive Mode Commands-n (Configure iSCSI Settings)5-4 SN0054621-00 BQ5.9-n(Configure iSCSI Settings)Type the following command to set to

Strona 58

5 – Non-interactive Mode Commands-pb (Bind Target)SN0054621-00 B 5-5Q5.10-pa(Add a Target)Type the following command to add persistent targets:-pa &l

Strona 59 - ■ Host type

5 – Non-interactive Mode Commands-pu (Unbind Target)5-6 SN0054621-00 BQ5.13-pu(Unbind Target)Type the following command to unbind a persistently boun

Strona 60 - (Configure iSCSI Settings)

5 – Non-interactive Mode Commands-rwt (Perform Read/Write Buffer Test)SN0054621-00 B 5-7QWhere:5.18-lb(Perform Loopback Test)CAUTION! Before performi

Strona 61

5 – Non-interactive Mode Commands-dspchap (Display a CHAP Table)5-8 SN0054621-00 BQWhere:This command runs a read/write buffer test that writes an 8-

Strona 62

5 – Non-interactive Mode Commands-edchap (Edit a CHAP Entry)SN0054621-00 B 5-9Q5.22-linkchap(Assign a CHAP Entry to a Target)Type the following comma

Strona 63 - (Perform Loopback Test)

5 – Non-interactive Mode Commands-delchap (Delete a CHAP Entry)5-10 SN0054621-00 BQThe HBA will be reset after this command is issued.5.26-delchap(De

Strona 64 - -chapmap

5 – Non-interactive Mode Commands-rdh (Restore HBA Settings)SN0054621-00 B 5-11Q5.31-rdh(Restore HBA Settings)NOTE: This option is not supported in t

Strona 65

5 – Non-interactive Mode Commands-stat (Display HBA Statistics)5-12 SN0054621-00 BQ5.32-stat(Display HBA Statistics)Type the following command to dis

Strona 66

5 – Non-interactive Mode Commands-bootcodemode (Set Bootcode Mode (QLA4050/4052 and QMC4052 HBAs))SN0054621-00 B 5-13Q5.35-dnsdhcp(Configure IP Setti

Strona 67 - (Restore HBA Settings)

SANsurfer iSCSI HBA CLISN0054621-00 B Page viiQSANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus Ada

Strona 68

5 – Non-interactive Mode Commands-bootcode (Update Bootcode Code Image)5-14 SN0054621-00 BQWhere:DCHP mode (3) is valid only when DHCP is enabled.5.3

Strona 69

5 – Non-interactive Mode Commands-vpd (Display VPD Information)SN0054621-00 B 5-15Q5.44-csbootcode(Clear Secondary Primary Target Information)Type th

Strona 70

5 – Non-interactive Mode Commands-vpd (Display VPD Information)5-16 SN0054621-00 BQ

Strona 71

SN0054621-00 B Index-1IndexAAccept AEN 4-6Access control, firmware 4-6ACK, AFW_Delayed_Ack firmware parameter 4-7, 4-16, 4-18-addchap 5-9AddressIP 4-

Strona 72 - 5-16 SN0054621-00 B

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersIndex-2 SN0054621-00 BQ-binfo 5-13-bootcod

Strona 73

SANsurfer iSCSI HBA CLISN0054621-00 B Index-3QSANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus Adap

Strona 74

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersIndex-4 SN0054621-00 BQH-h 5-3HBAalias 4-2

Strona 75

SANsurfer iSCSI HBA CLISN0054621-00 B Index-5QSANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus Adap

Strona 76

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersIndex-6 SN0054621-00 BQR-r 5-6R2T, maximum

Strona 77

SANsurfer iSCSI HBA CLISN0054621-00 B Index-7QSANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus Adap

Strona 78

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersPage viii SN0054621-00 BQ5.31 -rdh (Restor

Strona 79

SANsurfer iSCSI HBA CLI Application User’s GuideCommand Line Interface for SANblade iSCSI Host Bus AdaptersIndex-8 SN0054621-00 BQ

Strona 80 - Index-8 SN0054621-00 B

SN0054621-00 B 1-1Section 1 IntroductionThe SANsurfer® command line interface (CLI) application is a simplified, condensed version of the SANsur

Komentarze do niniejszej Instrukcji

Brak uwag